AS 2047:2014

$91.00

Windows and external glazed doors in buildings

Published by Standards Australia, 09/23/2014

PDF

All of our standards are only available in PDF (Portable Document Format), an electronic, downloadable format.

Multi-User Access

After purchasing, you have the ability to assign each license to a specific user.

Printable

At any time, you are permitted to make printed copies for your and your members' reference use.

AS 2047, 2nd, 2014 – Windows and external glazed doors in buildings

AS 2047 specifies requirements, materials, construction, installation and glazing for external

(a) windows;
(b) sliding and swinging glazed doors, including French and bi-fold doors;
(c) adjustable louvres;
(d) shopfronts; and
(e) window walls with one-piece framing elements.

NOTE: Window walls do not include curtain walls using stacked or vertically spliced framing systems, manufactured from any material and installed in external walls of all classes of buildings.

Throughout this Standard, the term ‘window(s)’ means window of any type, including louvre(s) and glazed door(s).

NOTES:

1 The window ratings or classifications differ from previous glass and window Standards due to the more accurate evaluation of the effect of wind conditions. They are based on either AS 1170.2, or the specific wind loading code developed for housing, AS 4055.
2 For information on wind loads applicable to windows covered by this Standard, see Appendix A.
3 Prefabricated bay windows that incorporate sloped glass are classified as windows in external walls.
4 For the performance specifications of building facades, see AS/NZS 4284. Conformance to the requirements of AS/NZS 4284 will be deemed to satisfy the requirements of this Standard, provided the windows have been tested to AS 4420.1 (operating force test).
5 The following are not covered by this Standard but should be checked with the National Construction Code (NCC) for compliance requirements:

(a) Internal doors.
(b) Revolving glazed doors.
(c) Fixed louvres.
(d) Skylights and roof lights and windows in other than the vertical plane.
(e) Windows in greenhouses and agricultural buildings.
(f) Frameless sliding and swinging doors.
(g) Windows constructed on site and architectural one-off windows, which are not design tested.
(h) Second-hand windows, re-used windows or recycled windows.
(i) Heritage windows for heritage buildings, as defined by the relevant State or Territory authority.

General Product Information:

Committee BD-021
Purchase Note All current amendments available at time of purchase are included with the purchase of this document
Document Type PDF
ISBN 978 1 74342 839 9
Pages 72
Document Language English
Publisher Standards Australia
Status Current

Preview

Table of cotents

Preface
1 Scope and general
1.1 Scope
1.2 Normative references
1.3 Definitions
2 Performance
2.1 General
2.1.1 Performance criteria
2.1.2 Generic timber windows
2.2 Atmospheric environments
2.3 Window performance
2.3.1 Housing
2.3.1.1 General
2.3.1.2 Window ratings
2.3.1.3 Deflection/span ratio
2.3.1.4 Operating force
2.3.1.5 Air infiltration
2.3.1.6 Water penetration
2.3.1.7 Ultimate strength
2.3.2 Residential and commercial buildings
2.3.2.1 General
2.3.2.2 Design wind pressures
2.3.2.3 Deflection/span ratio
2.3.2.4 Operating force test
2.3.2.5 Air infiltration
2.3.2.6 Water penetration
2.3.2.7 Ultimate strength
2.3.3 Window energy rating
2.4 Verification of smaller or larger size products
2.5 Use and rating of window coupling systems
2.6 Substitution
3 Framing and finishes
3.1 Aluminium windows
3.1.1 Aluminium framing
3.1.1.1 Aluminium alloys
3.1.1.2 Extrusion alloys
3.1.1.3 Aluminium extrusions
3.1.1.4 Welding
3.1.1.5 Finishes
3.2 Timber windows
3.2.1 Timber framing
3.2.1.1 Durability
3.2.1.2 Sapwood susceptible to Lyctid borers
3.2.1.3 Moisture content
3.2.2 Permissible timber imperfections
3.2.2.1 Bow, spring and twist
3.2.2.2 Other imperfections
3.3 Unplasticized PVC (uPVC) windows
3.3.1 General
3.3.2 uPVC composition
3.3.3 Resistance to weathering
3.3.4 Impact strength
3.3.5 Recycled material
3.3.6 Tolerances
3.3.7 Inserts and external stiffeners
3.3.8 Additional considerations
3.4 Windows of other materials
3.4.1 Framing
3.4.1.1 General
3.4.1.2 Compatible materials
3.4.1.3 Tolerances
3.4.1.4 Finishes
4 Glazing
4.1 General
4.2 Glass
4.3 Glazing materials
5 Components
5.1 Hardware
5.2 Fasteners
5.2.1 Nails, screws and metal dowels
5.2.2 Adhesives
5.3 Weatherproofing
5.4 Security
5.5 Anchoring devices
6 Construction
6.1 General
6.2 Tolerances
6.3 Joints
6.4 Glazing
6.4.1 Glazed windows
6.4.2 Site glazing
6.5 Reveal linings
6.6 Flashings
7 Installation
7.1 Window selection
7.2 Installation
7.2.1 General
7.2.2 Flashing
7.3 Thermal and structural movement
7.3.1 General
7.3.2 Thermal movement
7.3.3 Structural movement
7.4 On-site care
8 Labelling and certificate
8.1 General
8.2 Labelling
8.3 Certificate
Appendix A
A1 Introduction
A2 Wind loads for housing
A2.1 General
A2.2 Local pressure effects near wall edge
A3 Wind loads for buildings other than housing
Appendix B
B1 General
B2 Durability
B2.1 General
B2.2 Atmospheric classifications
B3 Corrosion
Appendix C
Appendix D
D1 Anodizing
D2 Powder coating
D3 Liquid organic coating
D4 High-performance coating
Appendix E
Appendix F
F1 General
F2 Construction
Appendix G
Amendment control sheet
Bibliography